The KUS S5U-15 Liquid Level Sender monitors the level of water, gasoline, diesel, or hydraulic oil in compatible tanks. Its magnetic float and reed-switch sensing system provide reliable level readings without a traditional mechanical wiper arm. With a 15 in probe and 1.5 in NPT threaded mount, it connects to tanks equipped with a compatible sender port.

FEATURES
  • 15 in probe: Designed for compatible water and fuel tanks

  • American Standard output: 240 Ω empty to 33 Ω full

  • Magnetic float and reed-switch sensing system with no mechanical wiper arm

  • 316 stainless steel sender body and corrosion-resistant NBR float

  • IP65-rated sealed housing

  • Compatible with 12V and 24V systems

  • Suitable for water, gasoline, diesel, and hydraulic oil

SPECIFICATIONS
  • Probe length: 15 in

  • Mounting: 1.5 in NPT male thread with hex head

  • Output signal: 240–33 Ω (240 Ω empty, 33 Ω full)

  • Sensing method: Magnetic float with reed-switch chain

  • Resolution: 21 mm

  • Body material: SUS 316 stainless steel

  • Float material: NBR

  • Wire leads: PVC-jacketed, pink (ground) and black (signal)

  • Protection rating: IP65

  • Operating temperature: -40°F to +185°F (-40°C to +85°C)

  • Operating voltage: 12V or 24V DC systems

  • Power consumption: 125 mW

  • Manufacturer part number: KUS 154015

WHAT'S INCLUDED
  • 1 × KUS S5U-15 liquid level sender

INSTALLATION & COMPATIBILITY
  • Fits tanks equipped with a 1.5 in NPT sender port.

  • Connect the pink wire to ground and the black wire to the gauge sender terminal. No separate power feed is required.

  • Use a thread sealant compatible with the liquid stored in the tank.

  • Allow at least 1 in clearance between the tank bottom and float collar for plastic tanks, or 1/2 in for stainless steel and aluminum tanks.

  • Compatible with gauges using the American Standard 240–33 Ω resistance curve. Verify gauge compatibility before ordering.